Stonewood Exterior Architectural Panels Warranty (PDF)
Stonewood Panels are solid phenolic architectural panels (also referred to as compact laminate) manufactured by Fiberesin. Panels and planks are designed for use as open joint exterior cladding in a rainscreen design.
Versatile installation options include exposed and concealed fasteners, as well as a stackable mounting system.
Stonewood panels pass the rigorous NFPA 285 test and are offered in stunning designs to accent new and retrofit construction.
pdf
Printer Friendly Version
(102 KB)
View Miami-Dade NOA
Description | Test ID | NEMA Requirements | Class A & B |
Light Resistance | 3.3 | Slight Effect | Slight Effect |
Resistance to High Temperature | 3.6 | Slight Effect | No Effect |
Ball Drop Impact Resistance: | 3.8 | 75" | 90"+ |
Wear Resistance: | 3.13 | 400 Cycle Minimum | 700 Cycle |
Property | Direction | Class A & B |
Flexural Strength ASTM D-790 (PSI) | Machine Direction Cross Direction |
19,000 16,000 |
Flexural Modulus ASTM D-790 (PSI) | Machine Direction Cross Direction |
1.3 x 106 1.0 x 106 |
Tensile Modulus ASTM D-638 (PSI) | Machine Direction Cross Direction |
14,000 10,000 |
Description | Information | Class A | Class B |
Flame Spread Index - ASTM E-84 (BLDG) | Tests were performed on a 5/16" panel | ≤ 25 | ≤ 75 |
Smoke Developed Values - ASTM E-84 (BLDG) | Class B is considered to be the Standard Product. | ≤ 450 | ≤ 450 |
Weight Per Unit Area | |||
Thickness | 0.156" | 0.250" | 0.500" |
Density PCF | 86 ± 3 | 86 ± 3 | 86 ± 3 |
Lbs/ft2 | 1.12 ± 0.04 | 1.79 ± 0.06 | 3.58 ± 0.13 |
Kg/m2 | 5.47 ± 0.20 | 8.74 ± 0.29 | 17.47 ± 0.64 |
Description | Test Method | Requirements (3000 Hr) |
Grey Scale | DIN EN 438-2 29 | 3-4 |
Appearance | DIN EN 438-2 29 | 4 |
Measurement | Tolerance (in) |
Thickness (.156 to .375) | ± .020 |
Thickness (above .375 to 1.000) | ± .030 |
CNC Shaped size (Length -Width) | ± .020 |
Drill Diameter | ± .003 |
Drill Depth | ± .020 |
CNC Hole to hole | ± .020 |
CNC Hole to Edge (1 Oper) | ± .020 |
CNC Hole to Edge (2 Oper) | ± .030 |
Routing - (Slots Width and Length) | ± .015 |
Routing - (Slots Depth) | ± .020 |
Description | Information |
Miami Dade / Notice of Acceptance | Compliant |
Florida Product Approval / Validated | FL27934 |